Commercial Systems

COMMERCIAL SYSTEMS

The range of VRF interiors is combined with both Mini VRF exteriors and modular VRFs. The range has been sized to optimally meet comfort and air distribution needs, for both residential and commercial buildings, the tertiary sector and Hotels.

Functionality & Features

Acoustic Comfort

Acoustic comfort of indoor units

Quietness ensured by the special design of the high-efficiency centrifugal fan and scroll of ducted systems. Due to an optimal angle of air entry into the fan blades and the ratio of the inner and outer elements of the impeller, a large volume of air can be obtained with extremely low noise.
The expansion valve can be remote-controlled to bring the actual noise to only 22 dB(A).

High quietness of the outdoor unit (up to 45dB)

Exclusively designed fans and special compressor insulation make it possible to significantly reduce the noise level of the outdoor unit, bringing it down to as low as 45 dB(A) in some cases.

Reliability

Wide operating range in cooling

Our Mini VRF can provide cooling with outdoor temperatures from -5°C to +52°C.

Intelligent defrosting

During heating, the duration and frequency of defrost cycles are a function of certain factors such as outdoor temperature, load, and operating time.
The microprocessor analyzes all parameters and defines the defrosting time in real time by estimating the thickness of the ice layer, the working pressure and the surface area available for heat exchange.

Protected from strong headwinds

Our Mini VRF adopts technology that allows
it to effectively counteract even strong headwinds, for safe installation even in strongly windy areas.

Resistant to communication interference

Our systems adopt CAN-bus communication technology. The CAN-bus protocol is specially designed to operate in environments highly disturbed by the presence of electromagnetic waves. The communication cable can be laid without the need for a shielded cable.

Flexibility

Great flexibility of installation

Mini VRF units in this series can operate with extended refrigerant piping up to significant lengths.

Ease of handling

The compact size allows easy transportation even in an elevator.

Indoor units

Indoor units are versatile, quiet and suitable for various commercial settings. The main types include: Wall Units; Consoles; 4-Way Cassettes (60×60 and 90×90); Ducted Units.

Parete

Power from 2.2 to 7.1 kWHigh efficiency DC motorWide air diffusion

Specifications Models

Specifiche tecniche
TAD-VRFHW-22IT
Capacità nominale       kW:     2,20      2,50
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/49
Rated capacity (min.-max.) (EN14511) kW 2,20 2,50
Sound pressure [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 35-33-30
Sound power [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 45-43-40
Liquid tube diameter mm (in) 6,35 (1/4″)
Gas pipe diameter mm (in) 9,52 (3/8″)
Net dimensions (H./War./Pro.) mm 289/845/209
Net weight Kg 10,5
Specifiche tecniche
TAD-VRFHW-28IT
Capacità nominale       kW:     2,80      3,20
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (min.-max.) (EN14511) kW 2,80 3,20
Sound pressure [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 35-33-30
Sound power [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 45-43-40
Liquid tube diameter mm (in) 6,35 (1/4″)
Gas pipe diameter mm (in) 9,52 (3/8″)
Net dimensions (H./War./Pro.) mm 289/845/209
Net weight Kg 10,5
Specifiche tecniche
TAD-VRFHW-36IT
Capacità nominale       kW:     3,60      4,00
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (min.-max.) (EN14511) kW 3,60 4,00
Sound pressure [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 38-35-31
Sound power [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 48-45-41
Liquid tube diameter mm (in) 6,35 (1/4″)
Gas pipe diameter mm (in) 12,7 (1/2″)
Net dimensions (H./War./Pro.) mm 289/845/209
Net weight Kg 10,5
Specifiche tecniche
TAD-VRFHW-45IT
Capacità nominale       kW:     4,50      5,00
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (min.-max.) (EN14511) kW 4,50 5,00
Sound pressure [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 43-40-37
Sound power [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 53-50-47
Liquid tube diameter mm (in) 6,35 (1/4″)
Gas pipe diameter mm (in) 12,7 (1/2″)
Net dimensions (H./War./Pro.) mm 300/970/224
Net weight Kg 12,5
Specifiche tecniche
TAD-VRFHW-50IT
Capacità nominale       kW:     5,00      5,60
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (min.-max.) (EN14511) kW 5,00 5,60
Sound pressure [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 42-38-36
Sound power [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 52-48-46
Liquid tube diameter mm (in) 6,35 (1/4″)
Gas pipe diameter mm (in) 12,7 (1/2″)
Net dimensions (H./War./Pro.) mm 300/970/224
Net weight Kg 12,5
Specifiche tecniche
TAD-VRFHW-56IT
Capacità nominale       kW:     5,6      6,3
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/49
Rated capacity (min.-max.) (EN14511) kW 5,6 6.,3
Sound pressure [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 43
Sound power [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) n.a.
Liquid tube diameter mm (in) 9,52 (3/8″)
Gas pipe diameter mm (in) 15,9 (5/8″)
Net dimensions (H./War./Pro.) mm 246/1078/325
Net weight Kg 16
Specifiche tecniche
TAD-VRFHW-71IT
Capacità nominale       kW:     7,10      7,50
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (min.-max.) (EN14511) kW 7,10 7,50
Sound pressure [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 44
Sound power [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) n.a.
Liquid tube diameter mm (in) 9,52 (3/8″)
Gas pipe diameter mm (in) 15,9 (5/8″)
Net dimensions (H./War./Pro.) mm 246/1078/325
Net weight Kg 16

Download

Easy installation

The most widely used air distribution modefor great flexibility in positioning.

Easy maintenance

Not only the filter but also the front panel can be easily disassembled for more thorough cleaning.

Air distribution

Thanks to the wide air distribution angle, maximum comfort can be achieved even in very large rooms.

Console

Power from 2.8 to 5.0 kWDOUBLE AIR DELIVERYSIMPLIFIED INSTALLATION

Specifications Models

Specifiche tecniche
TAD-VRFCON-28IT
Capacità nominale       kW:     2,80      3,20
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (min.-max.) (EN14511) kW 2,80 3,20
Air flow rate (a.-m.-b.) m³/h 400-320-270
Sound pressure [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 38-33-27
Sound power [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A)
Liquid tube diameter mm (in) 6,35 (1/4″)
Gas pipe diameter mm (in) 9,52 (3/8″)
Net dimensions (H./War./Pro.) mm 600/700/215
Net weight Kg 16
Specifiche tecniche
TAD-VRFCON-36IT
Capacità nominale       kW:     3,60      4,00
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (min.-max.) (EN14511) kW 3,60 4,00
Air flow rate (a.-m.-b.) m³/h 480-400-310
Sound pressure [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 40-37-32
Sound power [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A)
Liquid tube diameter mm (in) 6,35 (1/4″)
Gas pipe diameter mm (in) 12,7 (1/2″)
Net dimensions (H./War./Pro.) mm 600/700/215
Net weight Kg 16
Specifiche tecniche
TAD-VRFCON-50IT
Capacità nominale       kW:     5,00      5,50
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (min.-max.) (EN14511) kW 5,00 5,50
Air flow rate (a.-m.-b.) m³/h 680-600-500
Sound pressure [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 40-43-39
Sound power [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A)
Liquid tube diameter mm (in) 6,35 (1/4″)
Gas pipe diameter mm (in) 12,7 (1/2″)
Net dimensions (H./War./Pro.) mm 600/700/215
Net weight Kg 16

Download

Silent operation

Thanks to the DC Motor Fan and its large diameter, large volumes of air can be distributed quietly

Air Distribution

With dual fan delivery, upper and lower, great temperature uniformity is achieved, improving comfort.

Value design

Easy to install, because of its uniform air distribution characteristic it provides ideal comfort and is aesthetically pleasing even in prestigious residential settings.

Simplified installation

It can be installed on the floor or slightly suspended for an even more elegant look.

Pavimento soffitto

Power from 2.8 to 7.1 kWAir distribution with horizontal and vertical oscillationDC Inverter Motor Fan

Specifications Models

Specifiche tecniche
TAD-VRFFC-28IT
Capacità nominale       kW:     2,80      3,20
Air conditioning Heating
Power supply
power supply
V/Ph/Hz 220-240/1/50
Rated capacity
(min.-max.) (EN14511)
kW 2,80 3,20
Air flow rate
(a.-m.-b.)
m³/h 600
Sound pressure (a.m.b.) dB(A) 36
Sound power dB(A) n.a.
Diameter
of liquid pipe
mm
(in)
6,35 (1/4″)
Diameter
of gas pipe
mm
(in)
9,52 (3/8″)
Net dimensions
(lt./Lar./Pro.)
mm 235/870/665
Net weight Kg 24

 

Specifiche tecniche
TAD-VRFHW-36IT
Capacità nominale       kW:     3,60      4,00
Air conditioning Heating
Power supply
power supply
V/Ph/Hz 220-240/1/50
Rated capacity
(min.-max.) (EN14511)
kW 3,60 4,00
Air flow rate
(a.-m.-b.)
m³/h 600
Sound pressure (a.m.b.) dB(A) 36
Sound power dB(A) n.a.
Diameter
of liquid pipe
mm
(in)
6,35 (1/4″)
Diameter
of gas pipe
mm
(in)
12,7 (1/2″)
Net dimensions
(lt./Lar./Pro.)
mm 235/870/665
Net weight Kg 24

 

Specifiche tecniche
TAD-VRFFC-56IT
Capacità nominale       kW:     5,60      6,30
Air conditioning Heating
Power supply
power supply
V/Ph/Hz 220-240/1/50
Rated capacity
(min.-max.) (EN14511)
kW 5,60 6,30
Air flow rate
(a.-m.-b.)
m³/h 750
Sound pressure (a.m.b.) dB(A) 42
Sound power dB(A) n.a.
Diameter
of liquid pipe
mm
(in)
9,52 (3/8″)
Diameter
of gas pipe
mm
(in)
15,9 (5/8″)
Net dimensions
(lt./Lar./Pro.)
mm 235/870/665
Net weight Kg 25

 

Specifiche tecniche
TAD-VRFFC-71IT
Capacità nominale       kW:     7,10      8,00
Air conditioning Heating
Power supply
power supply
V/Ph/Hz 220-240/1/50
Rated capacity
(min.-max.) (EN14511)
kW 7,10 8,00
Air flow rate
(a.-m.-b.)
m³/h 1350
Sound pressure (a.m.b.) dB(A) 44
Sound power dB(A) n.a.
Diameter
of liquid pipe
mm
(in)
9,52 (3/8″)
Diameter
of gas pipe
mm
(in)
15,9 (5/8″)
Net dimensions
(lt./Lar./Pro.)
mm 235/1200/665
Net weight Kg 32

 

Download

Frost protection

System equipped with frost protection, fan motor overload safety and safeguard in case of temperature sensor failure.

DC Inverter Motor

With a high capacity for speed regulation, this motor offers 30% improved efficiency over conventional motors.

Air distribution

With both horizontal and vertical oscillatory motion. The amplitude of the oscillation is greater, so as to provide superior comfort in home and work environments.

Cassette a 8 vie (60x60)

Power from 1.8 to 5.6 kWIntegrated condensate booster pumpINDEPENDENT FLAPS

Specifications Models

Specifiche tecniche
TAD-VRFCCAS-18IT
Capacità nominale       kW:     1,80      2,20
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (min.-max.) (EN14511) kW 1.80 2.20
Air flow rate (a.-m.-b.) m³/h 460/420/370
Sound pressure [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 33/30/25
Sound power [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 51/48/43
Liquid tube diameter mm (in) 6,35 (1/4″)
Gas pipe diameter mm (in) 9,52 (3/8″)
Unit net dimensions (H./War./Pro.) mm 265/570/570
Panel net dimensions (Alt./War./Pro.) mm 47,5/620/620
Unit net weight Kg 17,5
Panel net weight Kg 3,0
Specifiche tecniche
TAD-VRFCCAS-22IT
Capacità nominale       kW:     2,2      2,5
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (min.-max.) (EN14511) kW 2,2 2,5
Air flow rate (a.-m.-b.) m³/h 500/460/370
Sound pressure [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 36/31/25
Sound power [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) n.a.
Liquid tube diameter mm (in) 6,35 (1/4″)
Gas pipe diameter mm (in) 9,52 (3/8″)
Unit net dimensions (H./War./Pro.) mm 265/570/570
Panel net dimensions (Alt./War./Pro.) mm 47,5/620/620
Unit net weight Kg 17,5
Panel net weight Kg 3,0
Specifiche tecniche
TAD-VRFCCAS-28IT
Capacità nominale       kW:     2,80      3,20
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (min.-max.) (EN14511) kW 2.80 3.20
Air flow rate (a.-m.-b.) m³/h 570/480/420
Sound pressure [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 36/33/28
Sound power [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 54/51/46
Liquid tube diameter mm (in) 6,35 (1/4″)
Gas pipe diameter mm (in) 9,52 (3/8″)
Unit net dimensions (H./War./Pro.) mm 265/570/570
Panel net dimensions (Alt./War./Pro.) mm 47,5/620/620
Unit net weight Kg 17,5
Panel net weight Kg 3,0
Specifiche tecniche
TAD-VRFCCAS-36IT
Capacità nominale       kW:     3,60      4,00
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (min.-max.) (EN14511) kW 3.60 4.00
Air flow rate (a.-m.-b.) m³/h 620/550/480
Sound pressure [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 39/37/35
Sound power [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 57/55/53
Liquid tube diameter mm (in) 6,35 (1/4″)
Gas pipe diameter mm (in) 12,7 (1/2″)
Unit net dimensions (H./War./Pro.) mm 265/570/570
Panel net dimensions (Alt./War./Pro.) mm 47,5/620/620
Unit net weight Kg 17,5
Panel net weight Kg 3,0
Specifiche tecniche
TAD-VRFCCAS-45IT
Capacità nominale       kW:     4,5      5,0
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (min.-max.) (EN14511) kW 4,5 5,0
Air flow rate (a.-m.-b.) m³/h 730/650/560
Sound pressure [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 43/41/39
Sound power [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 61/59/57
Liquid tube diameter mm (in) 6,35 (1/4″)
Gas pipe diameter mm (in) 12,7 (1/2″)
Unit net dimensions (H./War./Pro.) mm 265/570/570
Panel net dimensions (Alt./War./Pro.) mm 47,5/620/620
Unit net weight Kg 17,5
Panel net weight Kg 3,0
Specifiche tecniche
TAD-VRFCCAS-56IT
Capacità nominale       kW:     5,60      6,30
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (min.-max.) (EN14511) kW 5.60 6.30
Air flow rate (a.-m.-b.) m³/h 730/650/560
Sound pressure [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 43/41/39
Sound power [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 61/59/57
Liquid tube diameter mm (in) 9,52 (3/8″)
Gas pipe diameter mm (in) 5/8
Unit net dimensions (H./War./Pro.) mm 265/570/570
Panel net dimensions (Alt./War./Pro.) mm 47,5/620/620
Unit net weight Kg 17,5
Panel net weight Kg 3,0

Download

Cassette a 8 vie (90x90)

Power from 2.2 to 16.0 kWIntegrated condensate booster pumpINDEPENDENT FLAPS

Specifications Models

Specifiche tecniche
TAD-VRFCAS-22IT
Capacità nominale       kW:     2,2      2,5
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (min.-max.) (EN14511) kW 2,2 2,5
Air flow rate (a.-m.-b.) m³/h 800-700-600
Sound pressure [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 32-29-27
Sound power [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 43-41-38
Liquid tube diameter mm (in) 6,35 (1/4″)
Gas pipe diameter mm (in) 9,52 (3/8″)
Unit net dimensions (H./War./Pro.) mm 200/840/840
Panel net dimensions (Alt./War./Pro.) mm 65/950/950
Unit net weight Kg 19
Panel net weight Kg 6
Specifiche tecniche
TAD-VRFCAS-28IT
Capacità nominale       kW:     2,80      3,20
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (min.-max.) (EN14511) kW 2,80 3,20
Air flow rate (a.-m.-b.) m³/h 800-700-600
Sound pressure [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 32-29-27
Sound power [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 43-41-38
Liquid tube diameter mm (in) 6,35 (1/4″)
Gas pipe diameter mm (in) 9,52 (3/8″)
Unit net dimensions (H./War./Pro.) mm 200/840/840
Panel net dimensions (Alt./War./Pro.) mm 65/950/950
Unit net weight Kg 19
Panel net weight Kg 6
Specifiche tecniche
TAD-VRFCAS-36IT
Capacità nominale       kW:     3,60      4,00
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (min.-max.) (EN14511) kW 3,60 4,00
Air flow rate (a.-m.-b.) m³/h 800-700-600
Sound pressure [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 32-29-27
Sound power [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 43-41-38
Liquid tube diameter mm (in) 6,35 (1/4″)
Gas pipe diameter mm (in) 12,7 (1/2″)
Unit net dimensions (H./War./Pro.) mm 200/840/840
Panel net dimensions (Alt./War./Pro.) mm 65/950/950
Unit net weight Kg 19
Panel net weight Kg 6
Specifiche tecniche
TAD-VRFCAS-45IT
Capacità nominale       kW:     4,50      5,00
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (min.-max.) (EN14511) kW 4,50 5,00
Air flow rate (a.-m.-b.) m³/h 900-800-700
Sound pressure [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 35-30-27
Sound power [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 45-37-36
Liquid tube diameter mm (in) 6,35 (1/4″)
Gas pipe diameter mm (in) 12,7 (1/2″)
Unit net dimensions (H./War./Pro.) mm 200/840/840
Panel net dimensions (Alt./War./Pro.) mm 65/950/950
Unit net weight Kg 19
Panel net weight Kg 6
Specifiche tecniche
TAD-VRFCAS-56IT
Capacità nominale       kW:     5,00      5,60
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (min.-max.) (EN14511) kW 5,00 5,60
Air flow rate (a.-m.-b.) m³/h 900-800-700
Sound pressure [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 35-30-27
Sound power [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 45-37-36
Liquid tube diameter mm (in) 6,35 (1/4″)
Gas pipe diameter mm (in) 12,7 (1/2″)
Unit net dimensions (H./War./Pro.) mm 200/840/840
Panel net dimensions (Alt./War./Pro.) mm 65/950/950
Unit net weight Kg 19
Panel net weight Kg 6
Specifiche tecniche
TAD-VRFCAS56AIT
Capacità nominale       kW:     5,6      6,3
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (min.-max.) (EN14511) kW 5,6 6,3
Air flow rate (a.-m.-b.) m³/h 1100-935-850
Sound pressure [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 37-35-32
Sound power [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 52-49-47
Liquid tube diameter mm (in) 9,52 (3/8″)
Gas pipe diameter mm (in) 15,9 (5/8″)
Unit net dimensions (H./War./Pro.) mm 200/840/840
Panel net dimensions (Alt./War./Pro.) mm 65/950/950
Unit net weight Kg 25
Panel net weight Kg 6
Specifiche tecniche
TAD-VRFCAS-71IT
Capacità nominale       kW:     7,1      8,0
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (min.-max.) (EN14511) kW 7,1 8,0
Air flow rate (a.-m.-b.) m³/h 1100-935-850
Sound pressure [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 37-35-32
Sound power [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 52-49-47
Liquid tube diameter mm (in) 9,52 (3/8″)
Gas pipe diameter mm (in) 15,9 (5/8″)
Unit net dimensions (H./War./Pro.) mm 200/840/840
Panel net dimensions (Alt./War./Pro.) mm 65/950/950
Unit net weight Kg 25
Panel net weight Kg 6
Specifiche tecniche
TAD-VRFCAS-90IT
Capacità nominale       kW:     9,0      10,0
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (min.-max.) (EN14511) kW 9,0 10,0
Air flow rate (a.-m.-b.) m³/h 1400-1000-900
Sound pressure [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 40-36-31
Sound power [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 53-50-44
Liquid tube diameter mm (in) 9,52 (3/8″)
Gas pipe diameter mm (in) 15,9 (5/8″)
Unit net dimensions (H./War./Pro.) mm 200/840/840
Panel net dimensions (Alt./War./Pro.) mm 65/950/950
Unit net weight Kg 27
Panel net weight Kg 6
Specifiche tecniche
TAD-VRFCAS-100IT
Capacità nominale       kW:     10,0      11,2
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (min.-max.) (EN14511) kW 10,0 11,2
Air flow rate (a.-m.-b.) m³/h 1450-1200-1100
Sound pressure [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 42-39-35
Sound power [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 58-51-49
Liquid tube diameter mm (in) 9,52 (3/8″)
Gas pipe diameter mm (in) 15,9 (5/8″)
Unit net dimensions (H./War./Pro.) mm 200/840/840
Panel net dimensions (Alt./War./Pro.) mm 65/950/950
Unit net weight Kg 27
Panel net weight Kg 6
Specifiche tecniche
TAD-VRFCAS-112IT
Capacità nominale       kW:     11,2      12,5
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (min.-max.) (EN14511) kW 11,2 12,5
Air flow rate (a.-m.-b.) m³/h 1450-1200-1100
Sound pressure [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 42-39-35
Sound power [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 58-51-49
Liquid tube diameter mm (in) 9,52 (3/8″)
Gas pipe diameter mm (in) 15,9 (5/8″)
Unit net dimensions (H./War./Pro.) mm 200/840/840
Panel net dimensions (Alt./War./Pro.) mm 65/950/950
Unit net weight Kg 27
Panel net weight Kg 6
Specifiche tecniche
TAD-VRFCAS-125IT
Capacità nominale       kW:     12,5      14,0
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (min.-max.) (EN14511) kW 12,5 14,0
Air flow rate (a.-m.-b.) m³/h 1800-1450-1150
Sound pressure [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 46-41-35
Sound power [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 60-55-47
Liquid tube diameter mm (in) 9,52 (3/8″)
Gas pipe diameter mm (in) 15,9 (5/8″)
Unit net dimensions (H./War./Pro.) mm 200/840/840
Panel net dimensions (Alt./War./Pro.) mm 65/950/950
Unit net weight Kg 29,5
Panel net weight Kg 6
Specifiche tecniche
TAD-VRFCAS-160IT
Capacità nominale       kW:     16,0      18,0
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (min.-max.) (EN14511) kW 16,0 18,0
Air flow rate (a.-m.-b.) m³/h 2000-1800-1430
Sound pressure [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 51-48-42
Sound power [sa.-a.-ma.-m.-mb.-b.-sb.] dB(A) 60-55-47
Liquid tube diameter mm (in) 9,52 (3/8″)
Gas pipe diameter mm (in) 19,05 (3/4″)
Unit net dimensions (H./War./Pro.) mm 200/840/840
Panel net dimensions (Alt./War./Pro.) mm 65/950/950
Unit net weight Kg 36
Panel net weight Kg 6

Download

New design for high quietness

The internal profiles and impeller are designed for even quieter operation reaching 25 db(A).

Self-protection functions

The unit is equipped with condensate leakage protection, anti-freeze and motor fan protection to ensure long product life.

Independent flaps

The 4 fins can be individually controlled to create a customized air distribution (requires flush control).

Canalizzabile bassa prevalenza

Power from 2.8 to 7.1 kWStatic pressure up to 50 PaIntegrated condensate booster pump

Specifications Models

Specifiche tecniche
TAD-VRFLSLIM-22IT
Capacità nominale       kW:     2,20      2,50
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (EN14511) kW 2,2 2,5
Air flow rate m³/h 450
Available static pressure Pa 5/0-30
Sound pressure (a.-m.-b) dB(A) 30
Sound power dB(A) 50-47-45
Liquid tube diameter mm (in) 6,35 (1/4″)
Gas pipe diameter mm (in) 9,52 (3/8″)
Net dimensions (H./War./Pro.) mm 200/710/462
Net weight Kg 18,5
Specifiche tecniche
TAD-VRFLSLIM-28IT
Capacità nominale       kW:     2,80      3,20
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (EN14511) kW 2,8 3,2
Air flow rate m³/h 450
Available static pressure Pa 5/0-50
Sound pressure (a.-m.-b) dB(A) 29-26-24
Sound power dB(A) 50-47-45
Liquid tube diameter mm (in) 6,35 (1/4″)
Gas pipe diameter mm (in) 9,52 (3/8″)
Net dimensions (H./War./Pro.) mm 198/540/462
Net weight Kg 13
Specifiche tecniche
TAD-VRFLSLIM-36IT
Capacità nominale       kW:     3,60      4,00
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (EN14511) kW 3,6 4,0
Air flow rate m³/h 550
Available static pressure Pa 5/0-50
Sound pressure (a.-m.-b) dB(A) 30-27-25
Sound power dB(A) 53-50-48
Liquid tube diameter mm (in) 6,35 (1/4″)
Gas pipe diameter mm (in) 12 (1/2″)
Net dimensions (H./War./Pro.) mm 198/700/462
Net weight Kg 15
Specifiche tecniche
TAD-VRFLSLIM-45IT
Capacità nominale       kW:     4,50      5,00
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (EN14511) kW 4,5 5,0
Air flow rate m³/h 750
Available static pressure Pa 5/0-50
Sound pressure (a.-m.-b) dB(A) 33-31-27
Sound power dB(A) 53-50-48
Liquid tube diameter mm (in) 6,35 (1/4″)
Gas pipe diameter mm (in) 12 (1/2″)
Net dimensions (H./War./Pro.) mm 198/900/462
Net weight Kg 19
Specifiche tecniche
TAD-VRFLSLIM-50IT
Capacità nominale       kW:     5,00      5,60
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/51
Rated capacity (EN14511) kW 5,0 5,6
Air flow rate m³/h 750
Available static pressure Pa 5/0-50
Sound pressure (a.-m.-b) dB(A) 33-31-27
Sound power dB(A) 53-50-48
Liquid tube diameter mm (in) 6,35 (1/4″)
Gas pipe diameter mm (in) 12 (1/2″)
Net dimensions (H./War./Pro.) mm 198/900/462
Net weight Kg 19

Download

7 levels of air flow rate

The DC motor can select 7 levels of air flow rate to match noise and air volume to the characteristics of the system.

Static pressure 80 Pa adjustable

Static pressure can be adjusted up to 80 Pa with 5 selectable pressure steps.

Outside air

an inlet is available to feed outside air into the room.

Flexible installation

The return can be provided from the rear or from below.

Canalizzabile media prevalenza

Power from 7.1 to 14.0 kWStatic pressure adjustable up to 80 PaSlim profile only 260 mm high

Specifications Models

Specifiche tecniche
TAD-VRFMSLIM-71IT
Capacità nominale       kW:     7,10      8,00
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (EN14511) kW 2,2 2,5
Air flow rate m³/h 1100/900/700
Available static pressure Pa 50/0-80
Sound pressure (a.-m.-b) dB(A) 37-34-31
Sound power dB(A) 59-55-53
Liquid tube diameter mm (in) 9,52 (3/8″)
Gas pipe diameter mm (in) 15,9 (5/8″)
Net dimensions (H./War./Pro.) mm 260/900/655
Net weight Kg 29,5
Specifiche tecniche
TAD-VRFMSLIM-90IT
Capacità nominale       kW:     9,0      10,0
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (EN14511) kW 9,0 10,0
Air flow rate m³/h 1700/1500/1100
Available static pressure Pa 50/0-80
Sound pressure (a.-m.-b) dB(A) 40/36/32
Sound power dB(A) 60/56/54
Liquid tube diameter mm (in) 9,52 (3/8″)
Gas pipe diameter mm (in) 15,9 (5/8″)
Net dimensions
(Alt./War./Pro.)
mm 260/1340/655
Net weight Kg 43,5

 

Specifiche tecniche
TAD-VRFMSLIM-112IT
Capacità nominale       kW:     11,12      12,5
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (EN14511) kW 11,2 12,5
Air flow rate m³/h 1700/1500/1100
Available static pressure Pa 50/0-80
Sound pressure (a.-m.-b) dB(A) 40/36/32
Sound power dB(A) 60/56/54
Liquid tube diameter mm (in) 9,52 (3/8″)
Gas pipe diameter mm (in) 15,9 (5/8″)
Net dimensions
(Alt./War./Pro.)
mm 260/1340/655
Net weight Kg 43,5

 

Specifiche tecniche
TAD-VRFMSLIM-140IT
Capacità nominale       kW:     14,0      16,0
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/51
Rated capacity (EN14511) kW 14,0 16,0
Air flow rate m³/h 2000/1700/1400
Available static pressure Pa 50/0-80
Sound pressure (a.-m.-b) dB(A) 42/40/37
Sound power dB(A) 61/57/54
Liquid tube diameter mm (in) 9,52 (3/8″)
Gas pipe diameter mm (in) 15,9 (5/8″)
Net dimensions
(Alt./War./Pro.)
mm 260/1340/655
Net weight Kg 43,5

 

Download

Medium prevalence

Static pressure can reach 80 Pa, making it particularly suitable for environments that require air distribution over large areas

Flexible installation

you can opt for a duct with a circular or rectangular cross-section, depending on your specific needs, or select different air intake modes.

Simple maintenance

Not only the filter but also the front panel can be easily disassembled for more thorough cleaning.

Canalizzabile alta prevalenza

2 models of 22.4 and 28 kW for large areasStatic pressure adjustable up to 200 PaAccess panels for easy maintenance

Specifications Models

Specifiche tecniche
TAD-VRFBDUC-224IT
Capacità nominale       kW:     22,4      25,0
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (EN14511) kW 22,4 25,0
Air flow rate m³/h 4000
Available static pressure Pa 100-(50-200)
Sound pressure (a.-m.-b) dB(A) 54
Sound power dB(A) 64-62-59
Liquid tube diameter mm (in) 9,52 (3/8″)
Gas pipe diameter mm (in) 19,05 (5/8″)
Net dimensions (H./War./Pro.) mm 385/1483/791
Net weight Kg 82
Specifiche tecniche
TAD-VRFBDUC-280IT
Capacità nominale       kW:     9,0      10,0
Air conditioning Heating
Power supply V/Ph/Hz 220-240/1/50
Rated capacity (EN14511) kW 28,0 31,0
Air flow rate m³/h 4400
Available static pressure Pa 100-(50-200)
Sound pressure (a.-m.-b) dB(A) 55
Sound power dB(A) 65/62/60
Liquid tube diameter mm (in) 9,52 (3/8″)
Gas pipe diameter mm (in) 22,2 (7/8″)
Net dimensions
(Alt./War./Pro.)
mm 450/1686/870
Net weight Kg 105

 

Download

9 levels of air flow rate

9 static pressure levels selectable, depending on the installation.

Static pressure

External static pressure rating high, with the possibility of adjustment from 50 to 250 Pa, either manually or automatically: this peculiarity is very important for applications where a very long air throw is needed.

Outdoor Units Mini VRF

Tadiran’s range of Mini VRFs features 3 single-phase models and 7 models three-phase, with the possibility of connecting 6 to 20 wall-mounted indoor units, consoles, ducted units and 8-way cassettes. You can connect indoor units for a capacity of 50% to 135% of the outdoor unit.

Monofase

4 to 5 HP12 to 16 kWUp to 20 indoor units

Specifications Models

Specifiche tecniche
TAD-VRFODU-4IT
Capacità nominale       kW:     12,10      13,00

 

Data
Capacity Capacity HP 4
Conditioning kW 12,1
Heating kW 13,0
Electrical parameters Power supply V/Ph/Hz 220-240/1/50
Cooling Rated input power kW 6.24
Max power kW 14.3
Rated current A 10.53
Max. current A 23.81
Heating Rated power input kW 5.25
Max power kW 11.69
Rated current A 8.86
Max. current A 19.47
SEER 7.25
SCOP 4.41
ηsc % 287
ηsh % 173
Specifiche tecniche
TAD-VRFODU-5IT
Capacità nominale       kW:     14,10      16,00
Data
Capacity Capacity HP 5
Conditioning kW 14,1
Heating kW 16,0
Electrical parameters Power supply V/Ph/Hz 220-240/1/50
Cooling Rated input power kW 7.37
Max power kW 15.1
Rated current A 12.44
Max. current A 25.14
Heating Rated power input kW 5.96
Max power kW 12.19
Rated current A 10.06
Max. current A 20.30
SEER 7.09
SCOP 4.31
ηsc % 281
ηsh % 169

Download

Trifase

6 to 7 HP16 to 22.4 kW18 to 24 kWUP TO 30 Internal Units

Specifications Models

Specifiche tecniche
TAD-VRFODU-6IT
Capacità nominale       kW:     16,0      18,5
Data
Cut HP 6
Capacity Conditioning kW 16,0
Heating kW 18,5
Power supply V/Ph/Hz 220-240/1/50
Electrical parameters Conditioning Rated input power kW 4,75
Rated current A 25,4
Heating Rated power input kW 4,65
Rated current A 24,8
Max power kW 6,8
Max. current A 31,5
Performance EER* 3,27
COP* 4,11
SEER 6,69
SCOP 4,31
ηsc % 265
ηsh % 169

 

Specifiche tecniche
TAD-VRFODUT-4IT
Capacità nominale       kW:     12,10      14,00
Data
Cut HP 4
Capacity Conditioning kW 12,1
Heating kW 14,0
Power supply V/Ph/Hz 380-415/3/50
Electrical parameters Conditioning Rated input power kW 3,03
Rated current A 5,4
Heating Rated power input kW 3,27
Rated current A 5,8
Max power kW 6,2
Max. current A 11,1
Performance EER* 4,08
COP* 4,07
SEER 6,70
SCOP 3,97
ηsc % 265
ηsh % 156

 

Specifiche tecniche
TAD-VRFODUT-5IT
Capacità nominale       kW:     14,00      16,50
Data
Cut HP 5
Capacity Conditioning kW 14,0
Heating kW 16,5
Power supply V/Ph/Hz 380-415/3/50
Electrical parameters Conditioning Rated input power kW 3,59
Rated current A 6,4
Heating Rated power input kW 3,95
Rated current A 7,1
Max power kW 6,7
Max. current A 12,0
Performance EER* 3,81
COP* 4,4
SEER 6,87
SCOP 4,26
ηsc % 272
ηsh % 167

 

Specifiche tecniche
TAD-VRFODUT-6IT
Capacità nominale       kW:     16,0      18,0
Data
Cut HP 6
Capacity Conditioning kW 16,0
Heating kW 18,0
Power supply V/Ph/Hz 380-415/3/50
Electrical parameters Conditioning Rated input power kW 4,75
Rated current A 8,5
Heating Rated power input kW 4,65
Rated current A 8,3
Max power kW 7,09
Max. current A 12,5
Performance EER* 3,27
COP* 4,1
SEER 6,95
SCOP 4,05
ηsc % 275
ηsh % 159

 

Specifiche tecniche
TAD-VRFODUT-7IT
Capacità nominale       kW:     22,40      24,00
Data
Cut HP 8
Capacity Conditioning kW 22,4
Heating kW 24,0
Power supply V/Ph/Hz 380-415/3/50
Electrical parameters Conditioning Rated input power kW 6,12
Rated current A 10,9
Heating Rated power input kW 4,9
Rated current A 8,8
Max power kW 9,6
Max. current A 17,2
Performance EER* 3,66
COP* 4,9
SEER 6,82
SCOP 4,31
ηsc % 270
ηsh % 169

 

Specifiche tecniche
TAD-VRFODUT-8IT
Capacità nominale       kW:     22,4      24,0
Data
Cut HP 8
Capacity Conditioning kW 22,4
Heating kW 24
Power supply V/Ph/Hz 380-415/3/50
Electrical parameters Conditioning Rated input power kW 4,9
Rated current A 10,9
Heating Rated power input kW 4,8
Rated current A 8,8
Max power kW 11,1
Max. current A 20,0
Performance EER* 4,55
COP* 5,23
SEER 6,85
SCOP 4,44
ηsc % 271
ηsh % 174
Specifiche tecniche
TAD-VRFODUT-10IT
Capacità nominale       kW:     28,0      31,5
Data
Cut HP 10
Capacity Conditioning kW 28,0
Heating kW 31,5
Power supply V/Ph/Hz 380-415/3/50
Electrical parameters Conditioning Rated input power kW 6,5
Rated current A 14,2
Heating Rated power input kW 6,2
Rated current A 11,5
Max power kW 12,5
Max. current A 25,0
Performance EER* 4,30
COP* 5,08
SEER 6,36
SCOP 4,68
ηsc % 251
ηsh % 184
Specifiche tecniche
TAD-VRFODUT-12IT
Capacità nominale       kW:     33,5      37,5
Data
Cut HP 12
Capacity Conditioning kW 33,5
Heating kW 37,5
Power supply V/Ph/Hz 380-415/3/50
Electrical parameters Conditioning Rated input power kW 8,1
Rated current A 16,1
Heating Rated power input kW 8,2
Rated current A 13,8
Max power kW 13,0
Max. current A 25,0
Performance EER* 4,14
COP* 4,58
SEER 6,78
SCOP 4,69
ηsc % 283
ηsh % 184

Download

VRF Modular Outdoor Units

Tadiran’s range of Modular VRF features 9 models, with the possibility of connecting from 16 to 45 wall, console, ducted and 8-way cassette indoor units. Indoor units can be connected for 50% to 135% capacity of the outdoor unit.

8-12HP

8 to 18HPUp to 45 units

Specifications Models

Specifiche tecniche
TAD-VRFODUM-8IT
Capacità nominale       kW:     12,10      13,00

 

Data
Capacity Size HP 8
Conditioning kW 22,4
Heating kW 25
Power supply V/Ph/Hz 380-415/3/50
Electrical parameters Conditioning Rated input power kW n.a.
Rated current A n.a.
Heating Rated power input kW n.a.
Rated current A n.a.
Max power kW 12,9
Max. current A 27,0
Performance EER* 4,38
COP* 5,02
SEER 7,5
SCOP 4,6
ηsc % 296,6
ηsh % 181,8
Specifiche tecniche
TAD-VRFODUM-10IT
Capacità nominale       kW:     28,0      31,5
Data
Capacity Size HP 10
Conditioning kW 28,0
Heating kW 31,5
Power supply V/Ph/Hz 380-415/3/50
Electrical parameters Conditioning Rated input power kW n.a.
Rated current A n.a.
Heating Rated power input kW n.a.
Rated current A n.a.
Max power kW 13,2
Max. current A 27,5
Performance EER* 3,7
COP* 4,21
SEER 7,2
SCOP 4,6
ηsc % 285,4
ηsh % 181,0

 

Specifiche tecniche
TAD-VRFODUM-12IT
Capacità nominale       kW:     33,5      37,5
Data
Capacity Size HP 12
Conditioning kW 33,5
Heating kW 37,5
Power supply V/Ph/Hz 380-415/3/50
Electrical parameters Conditioning Rated input power kW n.a.
Rated current A n.a.
Heating Rated power input kW n.a.
Rated current A n.a.
Max power kW 14,0
Max. current A 28,0
Performance EER* 3,44
COP* 4,27
SEER 7,2
SCOP 4,6
ηsc % 283,0
ηsh % 179,8

Download

14-24HP

14 to 24 HPUp to 45 units

Specifications Models

Specifiche tecniche
TAD-VRFODUM-14IT
Capacità nominale       kW:     14,10      16,00
Data
Capacity Size HP 14
Conditioning kW 40,0
Heating kW 45,0
Power supply V/Ph/Hz 380-415/3/50
Electrical parameters Conditioning Rated input power kW n.a.
Rated current A n.a.
Heating Rated power input kW n.a.
Rated current A n.a.
Max power kW 18,0
Max. current A 38,0
Performance EER* 3,83
COP* 4,28
SEER 7,4
SCOP 4,6
ηsc % 291,4
ηsh % 179,0

 

Specifiche tecniche
TAD-VRFODUM-16IT
Capacità nominale       kW:     12,10      14,00
Data
Capacity Size HP 16
Conditioning kW 45,0
Heating kW 50
Power supply V/Ph/Hz 380-415/3/50
Electrical parameters Conditioning Rated input power kW n.a.
Rated current A n.a.
Heating Rated power input kW n.a.
Rated current A n.a.
Max power kW 18,6
Max. current A 38,5
Performance EER* 3,43
COP* 4,11
SEER 7,3
SCOP 4,8
ηsc % 287,8
ηsh % 187,4

 

Specifiche tecniche
TAD-VRFODUM-18IT
Capacità nominale       kW:     14,00      16,50
Data
Capacity Size HP 18
Conditioning kW 50,4
Heating kW 56,5
Power supply V/Ph/Hz 380-415/3/50
Electrical parameters Conditioning Rated input power kW n.a.
Rated current A n.a.
Heating Rated power input kW n.a.
Rated current A n.a.
Max power kW 18,6
Max. current A 38,5
Performance EER* 3,47
COP* 4,11
SEER 7,1
SCOP 4,7
ηsc % 281,0
ηsh % 183,4

 

Specifiche tecniche
TAD-VRFODUM-20IT
Capacità nominale       kW:     16,0      18,5
Data
Capacity Size HP 20
Conditioning kW 56,0
Heating kW 63,0
Power supply V/Ph/Hz 380-415/3/50
Electrical parameters Conditioning Rated input power kW n.a.
Rated current A n.a.
Heating Rated power input kW n.a.
Rated current A n.a.
Max power kW 22,0
Max. current A 39,3
Performance EER* 3,54
COP* 3,83
SEER 6,9
SCOP 4,3
ηsc % 271,8
ηsh % 167,4

 

Specifiche tecniche
TAD-VRFODUM-22IT
Capacità nominale       kW:     22,40      24,00
Data
Capacity Size HP 22
Conditioning kW 61,5
Heating kW 69,0
Power supply V/Ph/Hz 380-415/3/50
Electrical parameters Conditioning Rated input power kW n.a.
Rated current A n.a.
Heating Rated power input kW n.a.
Rated current A n.a.
Max power kW 25,8
Max. current A 46,1
Performance EER* 3,25
COP* 3,85
SEER 6,7
SCOP 4,4
ηsc % 265,8
ηsh % 172,2

 

Specifiche tecniche
TAD-VRFODUM-24IT
Capacità nominale       kW:     22,4      28,0
Data
Capacity Size HP 24
Conditioning kW 68,0
Heating kW 76,5
Power supply V/Ph/Hz 380-415/3/50
Electrical parameters Conditioning Rated input power kW n.a.
Rated current A n.a.
Heating Rated power input kW n.a.
Rated current A n.a.
Max power kW 27,4
Max. current A 49,0
Performance EER* 3,28
COP* 3,8
SEER 6,5
SCOP 4,2
ηsc % 255,0
ηsh % 165,0

Download

Features

Efficiency

- New generation compressor
- Sensor-free DC Inverter
- Fan motor
- High control steam injection with double expansion valve (EEV)
- Multi EEV control technology

Intelligent defrosting

New generation of intelligent defrosting, thanks to advanced cooling and heating technology

Heat exchanger

- High efficiency
- Dual zone stratified heat exchanger
- Unique fan blade design
- Golden Fin protection

Noise control

- High airflow and reduced noise ventilation
- Sound insulation and soundproofing
- Better acoustic control of vapor injection
- Reduced remore of refrigerant flow
- "Intelligent quite control"

Sensorless dc inverter fan motor

Linear speed regulation operates in the range of 5 to 65 Hz. Compared with conventional inverter motors, this system provides greater energy efficiency. In addition, sensorless control technology ensures quieter operation, with reduced vibration.

Smart control

- Dual energy-saving modes
- Efficient modular control (HPAC)
- Self-adaptive load control (SRL)
- Intelligent circuit control of refrigerant

Oil balance control technology

The outdoor units are designed to ensure oil balancing between the different modules, eliminating the need to install a dedicated connecting pipe. This arrangement significantly simplifies installation operations.

CONTACTS

Are you interested or need more information? Contact us