Heat Pumps

HEAT PUMPS

The Tadiran heat pump series is among the most comprehensive on the market.
Packaged units are offered with both R32 and R290 chillers, which are complemented by the Split series at R32 with the indoor module that can be easily integrated into a wall cabinet in the home. The range is completed with the new Hydro Split at R290 with hydronic connections between outdoor unit and indoor unit, the latter prepared with an integrated 200L tank.

Functionality & Features

Maximum Comfort

Constant Capacity

Heat pumps can normally work even at -25°C outside, and the heat capacity remains constant down to -10°C.

Energy Efficiency up to A+++

SCOP with water at 35°C/55°C reaches Class A+++.

Protection for Security

A special separation device between refrigerant and water side prevents refrigerant from mixing with water or entering the environment.
Electronic boards have special protection against fire hazards to ensure maximum safety.

Hot water production up to 80°.

The unit can produce hot water at 80°C making it an ideal solution even with high-temperature terminals.

High Quietness

These monoblock units have a sound pressure at 3m of only 35 db(A).

Bizona Control

Two zones with separate circuits can be defined, managing the two temperatures separately.

Antilegionella

The function can be set manually or programmed. Water can be heated to 75°C for the sterilization cycle.
The user can recognize when the cycle is in progress by the icon shown by the display.

Climate Curves

Through the climate management function, zone 1 and zone 2 can be automatically managed according to the outdoor temperature.

Smart Grid

The units are already equipped with Smart Grid function for intelligent grid management.

Wi-Fi

Tadiran air conditioning systems have built-in Wi-Fi technology. With smart connectivity, you can control the temperature, operation mode, and timer directly from your smartphone or tablet, wherever you are, via an intuitive and easy-to-use app.

Manage the climate of your home at any time

The MY TADIRAN EU app allows you to control air conditioners throughout your home and manage your air conditioning from your cell phone. Using the app you can control the temperature of each room, define the climate of your home, set a timer or set on/off times even when you are away from home, on Saturdays and holidays.

Extend the warranty up to 5 years on Mono-Multi Split!

Activation of My Tadiran automatically allows you to get anextension to +5 years* of warranty on all parts of single-multi split products (excluding labor), in addition to the 2 years of full coverage.

For all other products, the warranty is 2 years full coverage + 3 on replacement parts ( excluding labor)

*If you purchased a mono-multi split before 07/31/2025.

YEARS OF WARRANTY!

Activating My Tadiran automatically allows you to get an extension to +3 years warranty on all parts (excluding labor)

Monoblock

They are compact heating, cooling, and domestic hot water systems in which all components are integrated into a single outdoor unit.
They work by transferring heat from the outdoor air to the system water, without the need for an indoor unit.

MONOBLOCK HEAT PUMPS
WITH R32 REFRIGERANT

Monofase

WITH R32Power from 5 to 8.5 kWMAX DISCHARGE TEMP 60°A++
Suitable for small and medium-sized homes and businesses

Specifications Models

Specifiche tecniche
TAD-ATWM052IT
Data
Heating (LWT 35℃ / OAT 7℃) Capacity kW 5,00
Absorbed Power kW 0,99
COP W/W 5,06
Heating (LWT 55℃ / OAT 7℃) Capacity kW 5,00
Absorbed Power kW 1,69
COP W/W 2,95
Heating
Climate Medium water outlet 35℃
SCOP 4,97
ηs % 196
Energy Class A+++
Heating
Climate Medium water outlet 55℃
SCOP 3,52
ηs % 138
Energy Class A++
Cooling (LWT 18℃ / OAT 35℃) Capacity kW 5,00
Absorbed Power kW 1,02
EER 4,90
Specifiche tecniche
TAD-ATWM072IT
Data
Heating (LWT 35℃ / OAT 7℃) Capacity kW 7,00
Absorbed Power kW 1,40
COP W/W 5,00
Heating (LWT 55℃ / OAT 7℃) Capacity kW 7,00
Absorbed Power kW 2,41
COP W/W 2,90
Heating
Climate Medium water outlet 35℃
SCOP 4,95
ηs % 195
Energy Class A+++
Heating
Climate Medium water outlet 55℃
SCOP 3,38
ηs % 132
Energy Class A++
Cooling (LWT 18℃ / OAT 35℃) Capacity kW 7,00
Absorbed Power kW 1,44
EER 4,85
Specifiche tecniche
TAD-ATWM092IT
Data
Heating (LWT 35℃ / OAT 7℃) Capacity kW 9,00
Absorbed Power kW 1,84
COP W/W 4,90
Heating (LWT 55℃ / OAT 7℃) Capacity kW 8,50
Absorbed Power kW 3,09
COP W/W 2,75
Heating
Climate Medium water outlet 35℃
SCOP 4,95
ηs % 195
Energy Class A+++
Heating
Climate Medium water outlet 55℃
SCOP 3,34
ηs % 131
Energy Class A++
Cooling (LWT 18℃ / OAT 35℃) Capacity kW 8,00
Absorbed Power kW 1,86
EER 4,30

Download

Trifase

WITH R32Power from 10.5 to 15.2 kWMAX DISCHARGE TEMP 60°A++
Suitable for large buildings and installations with high loads

Specifications Models

Specifiche tecniche
TAD-ATWM11IT
Data
Heating (LWT 35℃ / OAT 7℃) Capacity kW 11,00
Absorbed Power kW 2,24
COP W/W 4,90
Heating (LWT 55℃ / OAT 7℃) Capacity kW 10,50
Absorbed Power kW 3,50
COP W/W 3,00
Heating
Climate Medium water outlet 35℃
SCOP 4,70
ηs % 185
Energy Class A+++
Heating
Climate Medium water outlet 55℃
SCOP 3,40
ηs % 133
Energy Class A++
Cooling (LWT 18℃ / OAT 35℃) Capacity kW 10,00
Absorbed Power kW 2,27
EER 4,40
Specifiche tecniche
TAD-ATWMT14IT
Data
Heating (LWT 35℃ / OAT 7℃) Capacity kW 14,00
Absorbed Power kW 2,95
COP W/W 4,75
Heating (LWT 55℃ / OAT 7℃) Capacity kW 13,50
Absorbed Power kW 4,82
COP W/W 2,80
Heating
Climate Medium water outlet 35℃
SCOP 4,65
ηs % 183
Energy Class A+++
Heating
Climate Medium water outlet 55℃
SCOP 3,45
ηs % 135
Energy Class A++
Cooling (LWT 18℃ / OAT 35℃) Capacity kW 13,50
Absorbed Power kW 3,14
EER 4,30
Specifiche tecniche
TAD-ATWM16IT
Data
Heating (LWT 35℃ / OAT 7℃) Capacity kW 16,00
Absorbed Power kW 3,53
COP W/W 4,53
Heating (LWT 55℃ / OAT 7℃) Capacity kW 15,20
Absorbed Power kW 5,53
COP W/W 2,75
Heating
Climate Medium water outlet 35℃
SCOP 4,55
ηs % 179
Energy Class A+++
Heating
Climate Medium water outlet 55℃
SCOP 3,40
ηs % 133
Energy Class A++
Cooling (LWT 18℃ / OAT 35℃) Capacity kW 15,20
Absorbed Power kW 3,80
EER 4,00

Download

MONOBLOCK HEAT PUMPS
WITH R290 REFRIGERANT

Monofase

WITH R290Power from 4 to 8 kWMAX DISCHARGE TEMP 60°A+++
Suitable for small and medium-sized homes and businesses

Specifications Models

Specifiche tecniche
TAD-ATW29M042IT
Data
Heating (LWT 35℃ / OAT 7℃) Capacity kW 4,00
Absorbed Power kW 0,73
COP W/W 5,50
Heating (LWT 55℃ / OAT 7℃) Capacity kW 4,00
Absorbed Power kW 1,19
COP W/W 3,35
Heating
Climate Medium water outlet 35℃
SCOP ~ 5,10
ηs % 201
Energy Class A+++
Heating
Climate Medium water outlet 55℃
SCOP 3,85
ηs % 151
Energy Class A+++
Cooling (LWT 18℃ / OAT 35℃) Capacity kW 4,00
Absorbed Power kW 0,79
EER 5,05
Specifiche tecniche
TAD-ATW29M062IT
Data
Heating (LWT 35℃ / OAT 7℃) Capacity kW 6,00
Absorbed Power kW 1,12
COP W/W 5,35
Heating (LWT 55℃ / OAT 7℃) Capacity kW 6,00
Absorbed Power kW 1,82
COP W/W 3,30
Heating
Climate Medium water outlet 35℃
SCOP ~ 5,10
ηs % 201
Energy Class A+++
Heating
Climate Medium water outlet 55℃
SCOP 3,83
ηs % 150
Energy Class A+++
Cooling (LWT 18℃ / OAT 35℃) Capacity kW 6,00
Absorbed Power kW 1,20
EER 5,00
Specifiche tecniche
TAD-ATW29M082IT
Data
Heating (LWT 35℃ / OAT 7℃) Capacity kW 8,00
Absorbed Power kW 1,50
COP W/W 5,35
Heating (LWT 55℃ / OAT 7℃) Capacity kW 8,00
Absorbed Power kW 2,35
COP W/W 3,40
Heating
Climate Medium water outlet 35℃
SCOP ~ 5,20
ηs % 205
Energy Class A+++
Heating
Climate Medium water outlet 55℃
SCOP 3,85
ηs % 151
Energy Class A+++
Cooling (LWT 18℃ / OAT 35℃) Capacity kW 7,50
Absorbed Power kW 1,58
EER 4,75
Specifiche tecniche
TAD-ATW29M102IT
Data
Capacity kW 10,00
Absorbed Power kW 1,96
COP W/W 5,10
Heating (LWT 55℃ / OAT 7℃) Capacity kW 10,00
Absorbed Power kW 3,13
COP W/W 3,20
Heating
Climate Medium water outlet 35℃
SCOP ~ 5,10
ηs % 201
Energy Class A+++
Heating
Climate Medium water outlet 55℃
SCOP 3,83
ηs % 150
Energy Class A+++
Cooling (LWT 18℃ / OAT 35℃) Capacity kW 9,50
Absorbed Power kW 2,21
EER 4,30

Download

Trifase

WITH R290Power from 10 to 16 kWMAX DISCHARGE TEMP 60°A+++
Suitable for large buildings and installations with high loads

Specifications Models

Specifiche tecniche
TAD-ATW29MT12IT
Data
Heating (LWT 35℃ / OAT 7℃) Capacity kW 12,00
Absorbed Power kW 2,35
COP W/W 5,10
Heating (LWT 55℃ / OAT 7℃) Capacity kW 11,50
Absorbed Power kW 3,48
COP W/W 3,30
Heating
Climate Medium water outlet 35℃
SCOP ~ 4,82
ηs % 190
Energy Class A+++
Heating
Climate Medium water outlet 55℃
SCOP 3,85
ηs % 151
Energy Class A+++
Cooling (LWT 18℃ / OAT 35℃) Capacity kW 11,50
Absorbed Power kW 2,56
EER 4,50
Specifiche tecniche
TAD-ATW29MT14IT
Data
Heating (LWT 35℃ / OAT 7℃) Capacity kW 14,00
Absorbed Power kW 2,83
COP W/W 4,95
Heating (LWT 55℃ / OAT 7℃) Capacity kW 13,50
Absorbed Power kW 4,22
COP W/W 3,20
Heating
Climate Medium water outlet 35℃
SCOP ~ 4,80
ηs % 189
Energy Class A+++
Heating
Climate Medium water outlet 55℃
SCOP 3,83
ηs % 150
Energy Class A+++
Cooling (LWT 18℃ / OAT 35℃) Capacity kW 13,50
Absorbed Power kW 3,14
EER 4,30
Specifiche tecniche
TAD-ATW29MT16IT
Data
Heating (LWT 35℃ / OAT 7℃) Capacity kW 16,00
Absorbed Power kW 3,23
COP W/W 4,95
Heating (LWT 55℃ / OAT 7℃) Capacity kW 15,50
Absorbed Power kW 5,08
COP W/W 3,05
Heating
Climate Medium water outlet 35℃
SCOP ~ 4,80
ηs % 189
Energy Class A+++
Heating
Climate Medium water outlet 55℃
SCOP 3,85
ηs % 151
Energy Class A+++
Cooling (LWT 18℃ / OAT 35℃) Capacity kW 15,50
Absorbed Power kW 3,88
EER 4,00

Download

Split

Split-type heat pumps are a system for heating, cooling, and domestic hot water production, consisting of two separate units: an outdoor unit and an indoor unit; heat is exchanged between refrigerant and water in the heat exchanger of the indoor unit.
The two units are connected by pipes in which a refrigerant gas (e.g., R32) circulates.

Ideal for installation inside cabinets especially for homes in cold climates.

Unità esterna Monofase / Trifase

WITH R32Power From 4 to 10 kWA++

Specifications Models

Specifiche tecniche
TAD-ATWSODU042IT
Data
Heating (LWT 35℃ / OAT 7℃) Capacity kW 4,0
Absorbed Power kW 0,80
COP W/W 5,02
Heating (LWT 55℃ / OAT 7℃) Capacity kW 4
Absorbed Power kW 1.49
COP W/W 2.69
Heating
Climate Medium water outlet 35℃
SCOP (A++ to D) 5,00
ηs % 197
Energy Class A+++
Heating
Climate Medium water outlet 55℃
SCOP (A++ to D) 3,45
ηs % 135
Energy Class A++
Cooling (LWT 18℃ / OAT 35℃) Capacity kW 4
Absorbed Power kW 0,85
EER W/W 4,70
Specifiche tecniche
TAD-ATWSODU062IT
Data
Heating (LWT 35℃ / OAT 7℃) Capacity kW 6,0
Absorbed Power kW 1,20
COP W/W 4,98
Heating (LWT 55℃ / OAT 7℃) Capacity kW 6
Absorbed Power kW 2.18
COP W/W 2.75
Heating
Climate Medium water outlet 35℃
SCOP (A++ to D) 4,80
ηs % 189
Energy Class A+++
Heating
Climate Medium water outlet 55℃
SCOP (A++ to D) 3,38
ηs % 132
Energy Class A++
Cooling (LWT 18℃ / OAT 35℃) Capacity kW 6
Absorbed Power kW 1,26
EER W/W 4,75
Specifiche tecniche
TAD-ATWSODU082IT
Data
Heating (LWT 35℃ / OAT 7℃) Capacity kW 8,0
Absorbed Power kW 1,60
COP W/W 5,00
Heating (LWT 55℃ / OAT 7℃) Capacity kW 8
Absorbed Power kW 2.82
COP W/W 2.84
Heating
Climate Medium water outlet 35℃
SCOP (A++ to D) 4,90
ηs % 193
Energy Class A+++
Heating
Climate Medium water outlet 55℃
SCOP (A++ to D) 3,32
ηs % 130
Energy Class A++
Cooling (LWT 18℃ / OAT 35℃) Capacity kW 8
Absorbed Power kW 1,90
EER W/W 4,20
Specifiche tecniche
TAD-ATWSODU102IT
Data
Heating (LWT 35℃ / OAT 7℃) Capacity kW 10,0
Absorbed Power kW 2,17
COP W/W 4,60
Heating (LWT 55℃ / OAT 7℃) Capacity kW 10
Absorbed Power kW 3.66
COP W/W 2.73
Heating
Climate Medium water outlet 35℃
SCOP (A++ to D) 4,85
ηs % 191
Energy Class A+++
Heating
Climate Medium water outlet 55℃
SCOP (A++ to D) 3,30
ηs % 129
Energy Class A++
Cooling (LWT 18℃ / OAT 35℃) Capacity kW 10
Absorbed Power kW 2,50
EER W/W 4,00

Download

Unità interna

MAX DISCHARGE TEMP 60°

Specifications Models

Specifiche tecniche
TAD-ATWS-IDU062IT
Efficiency Data
Heating (LWT 35℃ / OAT 7℃) Capacity kW 4,0
Absorbed Power kW 0,80
COP W/W 5,02
Heating (LWT 55℃ / OAT 7℃) Capacity kW 4
Absorbed Power kW 1.49
COP W/W 2.69
Heating
Climate Medium water outlet 35℃
SCOP (A++ to D) 5,00
ηs % 197
Energy Class A+++
Heating
Climate Medium water outlet 55℃
SCOP (A++ to D) 3,45
ηs % 135
Energy Class A++
Cooling (LWT 18℃ / OAT 35℃) Capacity kW 4
Absorbed Power kW 0,85
EER W/W 4,70
Specifiche tecniche
TAD-ATWS-IDU102IT
Efficiency Data
Heating (LWT 35℃ / OAT 7℃) Capacity kW 8,0
Absorbed Power kW 1,60
COP W/W 5,00
Heating (LWT 55℃ / OAT 7℃) Capacity kW 8
Absorbed Power kW 2.82
COP W/W 2.84
Heating
Climate Medium water outlet 35℃
SCOP (A++ to D) 4,90
ηs % 193
Energy Class A+++
Heating
Climate Medium water outlet 55℃
SCOP (A++ to D) 3,32
ηs % 130
Energy Class A++
Cooling (LWT 18℃ / OAT 35℃) Capacity kW 8
Absorbed Power kW 1,90
EER W/W 4,20

Download

Hydrosplit ATWA

HydroSplit ATWA heat pumps are a system for heating, cooling and domestic hot water production, consisting of two separate units. An indoor unit and an outdoor unit. The two units are connected by pipes in which water, not refrigerant gas, circulates. This solution reduces the risk of refrigerant leakage inside the home. It guarantees high energy performance.

Ideal for those seeking a balance between safety, performance and ease of installation

Unità esterna Monofase / Trifase

WITH R290Power from 4 to 16 kWA+++

Specifications Models

Specifiche tecniche
TAD-ATWA042IT
Data
Heating (LWT 35℃ / OAT 7℃) Capacity kW 4,00
Absorbed Power kW 0,73
COP W/W 5,50
Heating (LWT 55℃ / OAT 7℃) Capacity kW 4,00
Absorbed Power kW 1,19
COP W/W 3,35
Heating
Climate Medium water outlet 35℃
SCOP ~ 5,10
ηs % 201
Energy Class A+++
Heating
Climate Medium water outlet 55℃
SCOP 3,85
ηs % 151
Energy Class A+++
Cooling (LWT 18℃ / OAT 35℃) Capacity kW 4,00
Absorbed Power kW 0,79
EER 5,05
Cooling (LWT 7℃ / OAT 35℃) Capacity kW 3,50
Absorbed Power kW 0,95
EER W/W 3,70
Specifiche tecniche
TAD-ATWAOD062IT
Data
Heating (LWT 35℃ / OAT 7℃) Capacity kW 6,00
Absorbed Power kW 1,12
COP W/W 5,35
Heating (LWT 55℃ / OAT 7℃) Capacity kW 6,00
Absorbed Power kW 1,82
COP W/W 3,30
Heating
Climate Medium water outlet 35℃
SCOP ~ 5,10
ηs % 201
Energy Class A+++
Heating
Climate Medium water outlet 55℃
SCOP 3,83
ηs % 150
Energy Class A+++
Cooling (LWT 18℃ / OAT 35℃) Capacity kW 6,00
Absorbed Power kW 1,20
EER 5,00
Cooling (LWT 7℃ / OAT 35℃) Capacity kW 5,00
Absorbed Power kW 1,37
EER W/W 3,65
Specifiche tecniche
TAD-ATWAOD082IT
Data
Heating (LWT 35℃ / OAT 7℃) Capacity kW 8,00
Absorbed Power kW 1,50
COP W/W 5,35
Heating (LWT 55℃ / OAT 7℃) Capacity kW 8,00
Absorbed Power kW 2,35
COP W/W 3,40
Heating
Climate Medium water outlet 35℃
SCOP ~ 5,20
ηs % 205
Energy Class A+++
Heating
Climate Medium water outlet 55℃
SCOP 3,85
ηs % 151
Energy Class A+++
Cooling (LWT 18℃ / OAT 35℃) Capacity kW 7,50
Absorbed Power kW 1,58
EER 4,75
Cooling (LWT 7℃ / OAT 35℃) Capacity kW 6,80
Absorbed Power kW 1,97
EER W/W 3,45
Specifiche tecniche
TAD-ATWAOD102IT
Data
Heating (LWT 35℃ / OAT 7℃) Capacity kW 10,00
Absorbed Power kW 1,96
COP W/W 5,10
Heating (LWT 55℃ / OAT 7℃) Capacity kW 10,00
Absorbed Power kW 3,13
COP W/W 3,20
Heating
Climate Medium water outlet 35℃
SCOP ~ 5,10
ηs % 201
Energy Class A+++
Heating
Climate Medium water outlet 55℃
SCOP 3,83
ηs % 150
Energy Class A+++
Cooling (LWT 18℃ / OAT 35℃) Capacity kW 9,50
Absorbed Power kW 2,21
EER 4,30
Cooling (LWT 7℃ / OAT 35℃) Capacity kW 8,50
Absorbed Power kW 2,62
EER W/W 3,25
Specifiche tecniche
TAD-ATWAODUT12IT
Data
Heating (LWT 35℃ / OAT 7℃) Capacity kW 12,00
Absorbed Power kW 2,35
COP W/W 5,10
Heating (LWT 55℃ / OAT 7℃) Capacity kW 11,50
Absorbed Power kW 3,48
COP W/W 3,30
Heating
Climate Medium water outlet 35℃
SCOP ~ 4,82
ηs % 190
Energy Class A+++
Heating
Climate Medium water outlet 55℃
SCOP 3,85
ηs % 151
Energy Class A+++
Cooling (LWT 18℃ / OAT 35℃) Capacity kW 11,50
Absorbed Power kW 2,56
EER 4,50
Cooling (LWT 7℃ / OAT 35℃) Capacity kW 10,00
Absorbed Power kW 2,99
EER W/W 3,35
Specifiche tecniche
TAD-ATWAODUT14IT
Data
Heating (LWT 35℃ / OAT 7℃) Capacity kW 14,00
Absorbed Power kW 2,83
COP W/W 4,95
Heating (LWT 55℃ / OAT 7℃) Capacity kW 13,50
Absorbed Power kW 4,22
COP W/W 3,20
Heating
Climate Medium water outlet 35℃
SCOP ~ 4,80
ηs % 189
Energy Class A+++
Heating
Climate Medium water outlet 55℃
SCOP 3,83
ηs % 150
Energy Class A+++
Cooling (LWT 18℃ / OAT 35℃) Capacity kW 13,50
Absorbed Power kW 3,14
EER 4,30
Cooling (LWT 7℃ / OAT 35℃) Capacity kW 12,00
Absorbed Power kW 3,75
EER W/W 3,20
Specifiche tecniche
TAD-ATWAODUT16IT
Data
Heating (LWT 35℃ / OAT 7℃) Capacity kW 16,00
Absorbed Power kW 3,23
COP W/W 4,95
Heating (LWT 55℃ / OAT 7℃) Capacity kW 15,50
Absorbed Power kW 5,08
COP W/W 3,05
Heating
Climate Medium water outlet 35℃
SCOP ~ 4,80
ηs % 189
Energy Class A+++
Heating
Climate Medium water outlet 55℃
SCOP 3,85
ηs % 151
Energy Class A+++
Cooling (LWT 18℃ / OAT 35℃) Capacity kW 15,50
Absorbed Power kW 3,88
EER 4,00
Cooling (LWT 7℃ / OAT 35℃) Capacity kW 14,00
Absorbed Power kW 4,52
EER W/W 3,10

Download

Unità interna

MAX DISCHARGE TEMP 60°ACS IN CLASS A+200L TANK

Specifications Models

Specifiche tecniche
TAD-ATWAIDU102IT
Data
Heating (LWT 35℃ / OAT 7℃) Capacity kW 4,00
Absorbed Power kW 0,73
COP W/W 5,50
Heating (LWT 55℃ / OAT 7℃) Capacity kW 4,00
Absorbed Power kW 1,19
COP W/W 3,35
Heating
Climate Medium water outlet 35℃
SCOP ~ 5,10
ηs % 201
Energy Class A+++
Heating
Climate Medium water outlet 55℃
SCOP 3,85
ηs % 151
Energy Class A+++
Cooling (LWT 18℃ / OAT 35℃) Capacity kW 4,00
Absorbed Power kW 0,79
EER 5,05
Cooling (LWT 7℃ / OAT 35℃) Capacity kW 3,50
Absorbed Power kW 0,95
EER W/W 3,70
Specifiche tecniche
TAD-ATWAIDUT162IT
Data
Heating (LWT 35℃ / OAT 7℃) Capacity kW 16,00
Absorbed Power kW 3,23
COP W/W 4,95
Heating (LWT 55℃ / OAT 7℃) Capacity kW 15,50
Absorbed Power kW 5,08
COP W/W 3,05
Heating
Climate Medium water outlet 35℃
SCOP ~ 4,80
ηs % 189
Energy Class A+++
Heating
Climate Medium water outlet 55℃
SCOP 3,85
ηs % 151
Energy Class A+++
Cooling (LWT 18℃ / OAT 35℃) Capacity kW 15,50
Absorbed Power kW 3,88
EER 4,00
Cooling (LWT 7℃ / OAT 35℃) Capacity kW 14,00
Absorbed Power kW 4,52
EER W/W 3,10

Download

CONTACTS

Are you interested or need more information? Contact us